Your browser doesn't support javascript.
loading
Design of static three dimensional nail-plate system and comparative biomechanicai study in fixing femoral neck fracture / 中国矫形外科杂志
Orthopedic Journal of China ; (24)2006.
Artículo en Chino | WPRIM | ID: wpr-544114
ABSTRACT
[Objective]Design the Static Three Dimensional Screw-Plate system(STDSP), bring a new instrument for the treatment of femoral neck fractures, which has good biome chanical features of axial loading and rotation stability and can reestablish the loss of support of the posterior neck of fracture with posterior comminution. [Method]Design the STDSP. To the fracture group,one femur of each pair was randomly selected to be stabilized by STDSP, and the other was fixed by the three cancellous lag screws(TCS). Then the constructions were tested with axial loading or rotation to failure. The intact group were fixed and then taken out with the two methods, then tested with axial loading. [Result] (1)Rotation test Compare the loads of the same rotation angle and the loads of the same width the anterior gap of the osteotomy open, STDS group is bigger than TCS group(PTCS group (P

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Orthopedic Journal of China Año: 2006 Tipo del documento: Artículo

Similares