3.5 mm T-shaped LCP (Locking Compression Plate) Fixation for Unstable Distal Clavicular Fractures
Journal of the Korean Shoulder and Elbow Society ; : 41-45, 2008.
Artículo en Coreano | WPRIM | ID: wpr-55116
ABSTRACT

PURPOSE:

To review the clinical and radiological results after an open reduction and internal fixation with a T-shaped LCP for unstable distal clavicle fractures. MATERIALS AND

METHODS:

From February 2005 to June 2006, ten patients with distal clavicle Neer type II fractures were treated with an open reduction and internal fixation with a T-shaped LCP. Bony union was identified by plain radiography. The clinical results were analyzed according to the UCLA scoring system.

RESULTS:

The mean time to fracture union was 9weeks and union was achieved in all cases. The mean UCLA score was 33.4 (30-35); excellent in 8 cases and good in 2 cases. In one case, loosening of one distal screw was occured and mild AC joint subluxation was observed in another case.

CONCLUSION:

3.5 mm T-shaped LCP fixation is a useful technique for treating unstable distal clavicle fractures. This procedure provide stable fixation with no further AC joint injury.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Clavícula / Articulaciones Límite: Humanos Idioma: Coreano Revista: Journal of the Korean Shoulder and Elbow Society Año: 2008 Tipo del documento: Artículo