Establishment of the Control of Cyclovirobuxine D / 中药新药与临床药理
Traditional Chinese Drug Research & Clinical Pharmacology
;
(6)1993.
Artículo
en Chino
| WPRIM
| ID: wpr-572067
ABSTRACT
Objective To set up the reference standard of cyclovirobuxine D.Methods Thermal analysis,HPLC/MS,HPLC with terminal wavelength,HPLC with fluorescence derivation and with ultraviolet derivation,TLC and nonaqueous titration methods were applied to determine the content of cyclovirobuxine D control.Results Thermal analysis can not be used to analyse the purity of cyclovirobuxine D ,and HPLC/MS,HPLC with terminal wavelength,HPLC with fluorescence derivation and HPLC with ultraviolet derivation can obtain the same purity.Conclusion The methods used for the assay of cyclovirobuxine D control were practical.