Determination of eugenol in Bawei Tanxiang Pills by Capillary Gas Chromatography / 中成药
Chinese Traditional Patent Medicine ; (12)1992.
Artículo en Chino | WPRIM | ID: wpr-572478
ABSTRACT

AIM:

To establish a capillary GC-FID programmed temperature method for determining eugenol in Bawei Tanxiang Pills(Lignum Santali Albi, Flos Caryophylii, etc.).

METHODS:

Chromatography was performed on a 25m?0.25mm(0.25?m film thickness), SE-54 fused-silica capillary column coupled with a FID-detector. The internal standard was cyclohexanone.

RESULTS:

A good linearity was obtained in the range of 0.25?g~8?g of Eugenol with a correlation coefficient of 0.9993. The average recovery was 96.5%, the RSD was 2.4%.

CONCLUSION:

The established method was provided to be a reliable quantitative method for quality control of Bawei Tanxiang Pills.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Traditional Patent Medicine Año: 1992 Tipo del documento: Artículo