Management of complex retinal detachment with combined vitrectomy and intravitreal perfluorocarbon liquid injection / 医学研究生学报
Journal of Medical Postgraduates
;
(12)2003.
Artículo
en Chino
| WPRIM
| ID: wpr-583619
ABSTRACT
Objective:
To evaluate the advantage of perfluorocarbon liquid as a hydrokinetic manipulation tool during complex vitreoretinal surgery.Methods:
Forty-two eyes with complicated retinal detachment were treated with vitrectomy and intravitreal perfluorocarbon liquid injection. Postoperative tamponade were obtained with silicon oil or gas.Results:
Retinas were successfully reattached in all eyes intraoperatively, after a follow-up period of 3-6 months,34 of the 42 retinas (81%) remain attached .Conclusion:
Perfluorocarbon liquid is an ideal hydrokinetic manipulation tool during complex vitreoretinal surgery.