Review of 2597 cases of blood transfusion and evaluation of the appropriateness / 中国输血杂志
Chinese Journal of Blood Transfusion
; (12)1988.
Article
en Zh
| WPRIM
| ID: wpr-591234
Biblioteca responsable:
WPRO
ABSTRACT
Objective To investigate the clinical use of blood in Shenzhen,in order to make the blood transfusion more appropriate and safer.Methods The medical records of 2 597 blood transfusion receipts from 3 hospitals in 2006 were reviewed.The use of blood components in each department,unreasonable prescriptions of very small amount of blood transfusion,and the combined transfusion of RBC and plasma were analyzed.Results The proportion of reasonable transfusion of RBC,plasma,platelet concentrates and cryoprecipitate were 66.44%,24.65%,97.97% and 61.29%,respectively.These proportion were 91.54%,51.85%,98.86%,and 100%,respectively,in internal medicine department,and 50.22%,19.86%,89.58%,42.86%,respectively,in surgery department.Unreasonable prescription of low-volume blood transfusion and the combined transfusion of RBC and plasma were 47.05% and 51.17%.Conclusion Except for plasma transfusion,the internal medicine departments did fairly well in blood component transfusion.Since the unreasonable transfusion still exists,the clinical doctors should be further trained in the appropriate use of blood,and get rid of the old practice of whole-blood-dependence.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Blood Transfusion
Año:
1988
Tipo del documento:
Article