Decay in quality of Closed-Chest Compression over time on CPR
Journal of the Korean Society of Emergency Medicine ; : 34-38, 1998.
Artículo en Coreano | WPRIM | ID: wpr-61622
ABSTRACT

BACKGROUND:

Provision of early adequate chest compression remains a standard of care for optimal outcome in cardiopulmonary arrest. Inadequate chest compression during CPR may result in the insufficient blood flow to preserve critical organ function. Therefore, authors performed this study to characterize fatigue-induced deterioration in the adequacy of closed-chest compression performed over period 5 minutes and to determine whether CPR providers recognize the effects of fatigue on compression adequacy.

METHOD:

Prospectively we carried out the study with an electronic CPR teaching mannequin(ResusciAnnie with Skillmeter; Laerdal) placed on a patient stretcher. The mannequin was equipped with a real-time remote display that records the numbers of total and correct compressions. Compression are judged as correct by the mannequin if both depth and placement are appropriate in keeping with standard advanced cardiac life support guidelines. Our study subjects were 27 nurses and doctors, each with certification of BLS and experience of CPR in ED. Each subject performed a 5 minute session of chest compressions. Also subjects were asked to verbally indicate the point during their 5 minute compression period at which they felt too fatigued to provide effective compressions. For statistical analysis, one-way repeated-measures ANOVA and regression test was used.

RESULT:

The number of total compressions attempted per minute did not decrease significantly(P=.565). But we found 81.0% of compressions performed during the first 1 minute to be correct. The percentages for minutes 2 through 5 were decreased significantly as follows 73.0%, 68.0%, 65.0%, 57.0%(P=.0003). Regression analysis revealed a decrement in compression adequacy of 13.0% per minutes after the first 1 minute of compression. The time of indicated fatigue was 220+/-29 seconds(mean+/-SD)

CONCLUSION:

Although compression rate was maintained over time, chest compression quality declined significantly over the study period. Because CPR providers could not recognize their ability to provide proper compression, cardiac arrest team leaders should carefully monitor compression adequacy and change the CPR providers each 3 minutes during CPR to assure maximally effective care for patients receiving CPR.
Asunto(s)
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Tórax / Certificación / Estudios Prospectivos / Reanimación Cardiopulmonar / Apoyo Vital Cardíaco Avanzado / Fatiga / Nivel de Atención / Paro Cardíaco / Maniquíes Tipo de estudio: Estudio observacional Límite: Humanos Idioma: Coreano Revista: Journal of the Korean Society of Emergency Medicine Año: 1998 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Tórax / Certificación / Estudios Prospectivos / Reanimación Cardiopulmonar / Apoyo Vital Cardíaco Avanzado / Fatiga / Nivel de Atención / Paro Cardíaco / Maniquíes Tipo de estudio: Estudio observacional Límite: Humanos Idioma: Coreano Revista: Journal of the Korean Society of Emergency Medicine Año: 1998 Tipo del documento: Artículo