Cobalt Hexacyanoferrate-modified Graphene Platform Electrodeand Its Electrochemical Sensing toward Hydrogen Peroxide / 分析化学
Chinese Journal of Analytical Chemistry
;
(12): 830-836, 2017.
Artículo
en Chino
| WPRIM
| ID: wpr-619957
ABSTRACT
A large-area graphene platform electrode (GPE) was fabricated by transferring the chemical vapor deposition (CVD) graphene grown on Cu foils to polyethylene terephthalate (PET) substrates with the aid of polymethyl-methacrylate (PMMA).Then cobalt hexacyanoferrate (CoHCF) was electrodeposited on the GPE by cyclic voltammetry to obtain a CoHCF/GPE.The morphology and electrochemical properties of this electrode were studied by scanning electron microscope (SEM), electrochemical impedance spectroscopy (EIS) and the electrochemical measurements.Results showed that the electrode had favorable sensing effect toward H2O2.On the basis of this, a new nonenzyme H2O2 sensor was constructed.Under the optimal experimental conditions, the proposed sensor had a quick response to the addition of H2O2 (about 2 s) with a wide linear rang (5 × 10-3-1.2 mmol/L) and a low detection limit (7.1 nmol/L).This sensor was easy to fabricate and showed excellent stability and anti-interference ability.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Idioma:
Chino
Revista:
Chinese Journal of Analytical Chemistry
Año:
2017
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS