ABSTRACT

Objective:

To investigate the application value of thrombelastography(TEG) in coagulation monitoring for ACS patients.

Methods:

Totally 255 ACS patients were selected with coagulation monitoring by TEG.The patients were divided into none ST-segment elevation myocardial infarction (NSTEMI) group and ST-segment elevation myocardial infarction (STEMI) group.The clotting characteristics in different types of ACS patients were compared and analyzed.

Results:

The ACS patients had higher intensity of thrombosis (MA) and Angle value.D-dimer and MA were significantly different between NSTEMI group and STEMI group(P<0.01).The drug utilization in STEMI group was closer to the requirements of the guidelines.

Conclusion:

TEG shows high application value in coagulation monitoring for ACS patients.MA value and Angle value are more sensitive in evaluating hypercoaguable state.