Your browser doesn't support javascript.
loading
Long term clinical outcome of cataract patients with Toric intraocular lens implantation / 中华实验眼科杂志
Chinese Journal of Experimental Ophthalmology ; (12): 372-376, 2013.
Artículo en Chino | WPRIM | ID: wpr-636078
ABSTRACT
Background Epidemiological investigation showed that 15%-29% of patients with cataract have preexisting astigmatism of > 1.50 D.So to control astigmatism is very important to the improvement of visual function after cataract surgery.The implantation of Toric intraocular lens (IOL) is a new option for the correction of preexisting astigmatism during cataract surgery,now.Short-term clinical studies of cataract patients with AcrySof Toric IOL implantation have revealed a good stability.However,the evaluation of long-term clinical result is seldom.Objective This study was to evaluate the long-term clinical results of Toric intraocular lens(IOL) implantation.Methods A serial case-observational study was designed.One hundred and twenty eyes of 78 cataract patients were included in this study.Phacoemulsification combined with AcrySof Toric IOL implantation was performed and the patients received a 2-year follow-up.Uncorrected distance visual acuity (UCDVA),best corrected distance visual acuity(BCDVA),residual cylinder,IOL rotation,vector analysis and accuracy of astigmatic correction were clinically evaluated in 1 day,1 month,3 months,6 months,1 year and 2 years,respectively.Comparison of these results of different follow-up periods were made.Results Sixty-seven patients (101 eyes)finished the follow-up and 19patients(19 eyes)lost visit due to other diseases affected.At 2 years visit after AcrySof SN60TT implantation,UCDVA,BCDVA,residual cylinder,absolute value of IOL rotation degree,vector magnitude of surgically induced astigmatism (SIA) was 0.16 (0.20),0 (0.1),0.75 (0.5) D,(2.9± 1.8) °,(1.2 ± 0.6) D,and the correction index (CI)was 0.90±0.41.A positive correlation was found between SIA and TIA(r=0.74,P =0.000).Compared to 1 month,3,6 months and 1 year,there was a mild tendency of decrease in accuracy of astigmatism correction and CI.Residual cylinder and degree of IOL rotation at 2 years after surgery were also slightly higher.However these changes were not statistically significant (P>0.05).Conclusions After 2 years of follow-up,patients with AcrySof Toric implantation remain good visual acuity.AcrySof Toric IOL presents excellent long-term rotational stability and accuracy of astigmatism correction.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio observacional Idioma: Chino Revista: Chinese Journal of Experimental Ophthalmology Año: 2013 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio observacional Idioma: Chino Revista: Chinese Journal of Experimental Ophthalmology Año: 2013 Tipo del documento: Artículo