Your browser doesn't support javascript.
loading
EX - PRESS glaucoma drainage device combined with phacoemulsification in treatment of POAG with cataract / 国际眼科杂志(Guoji Yanke Zazhi)
International Eye Science ; (12): 1891-1893, 2017.
Artículo en Chino | WPRIM | ID: wpr-640913
ABSTRACT

AIM:

To observe the clinical effect of combined cataract and primary open-angle glaucoma underwent phacoemulsification and glaucoma drainage device implantation. ·

METHODS:

We selected in our hospital from January 2014 to February 2016, 42 cases (42 eyes) with primary open-angle glaucoma with cataract. According to random number table method, all of the patients were randomly divided into two groups, control group and study group. In control group, 21 patients ( 21 eyes ) underwent trabecular resection combined phacoemulsification;in study group patients, 21 patients ( 21 eyes ) , underwent EX-PRESS glaucoma drainage device combined phacoemulsification. Compared parameters included postoperative complications and filtering bleb, visual acuity, intraocular pressure ( IOP ) and other clinical indicators between two groups. ·

RESULTS:

Preoperative IOP of two groups was no significantly different (P>0. 05). Postoperative IOP at each time point was significantly lower than before treatment (P 0. 05). At 12wk after treatment, surgical success rate of study group was 95%, significantly higher than that of control group 71% (P0. 05). At 12wk after treatment, 21 patients in study group were shown as functional filtering bleb, while in the control group 18 cases was functional filtering bleb. ·

CONCLUSION:

Using EX-PRESS glaucoma drainage device combined with phacoemulsification in treating cataract with primary open-angle glaucoma is reliable, the curative effect is better than that by trabeculectomy combined with phacoemulsification treatment.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: International Eye Science Año: 2017 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: International Eye Science Año: 2017 Tipo del documento: Artículo