ABSTRACT

AIM:

To observe the efficacy and safety of small incision manual nuncleofragmentation technology in hard-nucleus cataract.

METHODS:

Fifty-four patients (54 eyes) were performed with small incision manual nucleofragmentation and intraocular lens implantation.Uncorrected-visual acuity,corrected-visual acuity and astigmatism were measured before and after surgery.Anterior segment of eye,retina,surgical complications were observed.

RESULTS:

Preoperative uncorrected vision(LogMAR) was 1.095±0.171,corrected vision (LogMAR) was 0.994±0.158.Postoperative uncorrected vision(LogMAR) was 0.321±0.214 and corrected vision(LogMAR) was 0.276±0.179 at 1wk after operation.Both had statistical significance compared with uncorrected vision(LogMAR) (t=27.052,P0.05).No severe complications occurred in all cases.

CONCLUSION:

The technology of small incision manual nuncleofragmentation in hard-nucleus cataract is proved to be safe and effective.