ABSTRACT
Introduction:
The sore throat and hoarseness are common complications during the postoperative period. We investigated differences of incidence and severity of sore throat and hoarseness according to methods of airway security.METHODS:
One hundred twelve patients, in ASA physical status class 1~2, were included in this study (58 males and 54 females). They were divided into three groups group 1 (n=42), intubated with endotracheal tube lubricated with normal saline; group 2 (n=40), intubated with endotracheal tube lubricated with 5% lidocaine ointment; group 3 (n=30), inserted with laryngeal mask airway (LMA) for airway security.RESULTS:
The incidence of sore throat and hoarseness were 78.6% and 54.8% in group 1, 35% and 30% in group 2, and 33.3% and 20.0% in group 3.CONCLUSIONS:
Both 5% lidocaine-lubricated endotracheal tube and laryngeal mask airway showed tendency of decreased incidence of postoperative sore throat and hoarseness but there are no statistical significance.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Periodo Posoperatorio
/
Faringitis
/
Ronquera
/
Incidencia
/
Máscaras Laríngeas
/
Lidocaína
Tipo de estudio:
Estudio de incidencia
/
Estudio pronóstico
Límite:
Humanos
/
Masculino
Idioma:
Coreano
Revista:
The Korean Journal of Critical Care Medicine
Año:
1997
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS