Cerclage Clamping Using Cerclage Passer for Reduction of Anterior and Posterior Column Fracture / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association
;
: 486-492, 2016.
Artículo
en Coreano
| WPRIM
| ID: wpr-651008
ABSTRACT
PURPOSE:
Both column and T-shaped acetabular fractures are frequently presented with difficulty in reduction. Incomplete reduction may cause traumatic arthritis in the hip joint, resulting in inferior clinical outcomes. The purpose of this study is to introduce our wiring technique and to report the clinical and radiological outcomes of such technique. MATERIALS ANDMETHODS:
Eight patients who underwent our proposed technique for having acetabular fracture with displaced quadrilateral plate between March 2013 and December 2014 were enrolled. All patients were followed-up more than 1 year. The wire passer was set up from an anterolateral aspect of the iliac crest to the greater sciatic notch, between the abductor muscle and the periosteum. The quadrilateral plate of acetabular fracture was reduced with wiring. Internal fixation was added to the pelvic brim. An analysis of the clinical and radiological outcomes was performed.RESULTS:
Reduction was performed within the 3 mm intra-articular step-off in all patients. The mean duration of union was 11.8 weeks (9-15 weeks). Five patients (62.5%) showed excellent results, and radiologically, three patients (37.5%) showed good results, and seven patients (87.5%) showed better than good results.CONCLUSION:
The cerclage wiring fixation technique using a large cerclage passer instrument can be a useful and safe reduction method in some cases of acetabular fractures.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Periostio
/
Artritis
/
Constricción
/
Articulación de la Cadera
/
Acetábulo
/
Métodos
Límite:
Humanos
Idioma:
Coreano
Revista:
The Journal of the Korean Orthopaedic Association
Año:
2016
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS