ABSTRACT
PURPOSE:
We analyzed the patterns and causative factors of early aseptic loosening after total knee arthroplasty (TKR) using a legacy posterior stabilized (LPS)-flex prosthesis. MATERIALS ANDMETHODS:
We examined 483 cases that occurred in 311 patients who underwent TKR using LPS-flex by single surgeon between August 2001 and March 2007 and who were followed-up for at least 2 years. The loosened group included 25 cases that exhibited early aseptic loosening on radiograph, the remaining 458 cases were regarded as the control group, and analysis was performed.RESULTS:
The mean loosening period was 34.7 months and femoral component loosening alone was found in 22 cases (88%). There were no statistically significant differences in age, body mass index, or pre-operative range of motion between the 2 groups, but varus deformity was more severe in the loosened group (mean 8.92degrees) than in the control group (mean 5.21degrees) (p=0.003). Protrusion of the femoral component proximally over posterior condyle of the distal femur were more prominent in the loosened group (mean 20.3%) than in the control group (mean 13.4%) (p=0.001).CONCLUSION:
Early loosening after TKR using LPS-flex prosthesis developed mostly in the femoral component. Choosing a proper size for the femoral component and cutting level for the distal femur should be considered.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Artroplastia
/
Prótesis e Implantes
/
Anomalías Congénitas
/
Índice de Masa Corporal
/
Rango del Movimiento Articular
/
Artroplastia de Reemplazo de Rodilla
/
Fémur
/
Rodilla
Límite:
Humanos
Idioma:
Coreano
Revista:
The Journal of the Korean Orthopaedic Association
Año:
2012
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS