Effects of the Body Position Changes on Upper Airway Caliber in Obstructive Sleep Apnea during Sleep / 대한이비인후과학회지
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 1242-1247, 2005.
Artículo en Coreano | WPRIM | ID: wpr-653952
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Obstructive sleep apnea (OSA) is the intermittent cessation of breathing during sleep due to the collapse of the pharyngeal airway. Pharyngeal collapsibility and oropharyngeal caliber are affected by the respiratory cycle and the body position. Several methods have been used to evaluate the states of upper airway in patients with OSA according to body positions during wakefulness, but there were no reports about the upper airway states according to body positions during sleep. The aim of this study is to evaluate the states of upper airway in patients with OSA according to body position changes during sleep. MATERIALS AND

METHOD:

Using a multi detector CT, we studied 10 patients with OSA. Each patient was scanned at supine position during the awake state and then induced to sleep using Midazolam. According to body positions (supine, decubitus, and prone), images were acquired during sleep state. The following 4 transverse levels were obtained to evaluate the minimal cross sectional area, collapsibility index, and airway volume 1) high retropalate level, 2) low retropalate level, 3) high retroglossal level, 4) low retroglossal level.

RESULTS:

During sleep, the upper airway cross sectional area was decreased and the airway wall collapsibility was increased. Cross sectional area and airway volume were larger at prone and decubitus positions than supine position. Airway wall collapsibility index was lower at prone and decubitus positions than at the supine position.

CONCLUSION:

In this study, we confirm that the upper airway collapsibility decreases and the airway caliber increases according to body position changes (prone, decubitus) during sleep. Furthermore, the decubitus position is better than the prone position for improving upper airway patency during sleep.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Respiración / Síndromes de la Apnea del Sueño / Vigilia / Midazolam / Tomografía Computarizada de Emisión / Posición Supina / Posición Prona / Apnea Obstructiva del Sueño Límite: Humanos Idioma: Coreano Revista: Korean Journal of Otolaryngology - Head and Neck Surgery Año: 2005 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Respiración / Síndromes de la Apnea del Sueño / Vigilia / Midazolam / Tomografía Computarizada de Emisión / Posición Supina / Posición Prona / Apnea Obstructiva del Sueño Límite: Humanos Idioma: Coreano Revista: Korean Journal of Otolaryngology - Head and Neck Surgery Año: 2005 Tipo del documento: Artículo