Your browser doesn't support javascript.
loading
Effect of DHS and compression screw on femoral intertrochanteric fractures / 中国矫形外科杂志
Orthopedic Journal of China ; (24)2006.
Artículo en Chino | WPRIM | ID: wpr-670976
ABSTRACT
[Objective]To discuss the effects of DHS and compression screw application on femoral intertrochanteric fracture.[Method]Internal fixation was performed with DHS,DHS and compression screw,Ender nail and proximal femoral anatomical plate in 185 patients with femoral intertrochanteric fracture.The main outcome measures were operation duration,coxa adducta rates and postoperative Sanders scoring.[Result]All patients were followed up for 9-48 months.Operation duration was similar in the four groups.There were significant differences in coxa adducta rates and postoperative Sander's scores.According to the Sander's scores,the excellent to good rates in DHS and compression screw,DHS,Ender nail and proximal femoral anatomical plate groups were 94.6%,85.3%,75.4% and 80.6%,respectively.The coax adducta rates were 2.4%,9.5%,22.2% and 19.2%,respectively.[Conclusion]All the four kinds of internal fixation can be used for femoral intertrochanteric fracture,but DHS and compression screw is the best one for its good restoration of joint function and has no or little complication.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Orthopedic Journal of China Año: 2006 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Orthopedic Journal of China Año: 2006 Tipo del documento: Artículo