Your browser doesn't support javascript.
loading
Determination of Cinobufagin and Resibufogenin in Qianglijiuxin Dripping Pills by HPLC / 中成药
Article en Zh | WPRIM | ID: wpr-681218
Biblioteca responsable: WPRO
ABSTRACT
Objective: To determine the contents of cinobufagin and resibufogenin in Qianglijiuxin Dripping Pills. Methods: The HPLC method was used at Kromasil C 18 column of 250mm?4.6mm, 5?m, 0.5% Dipotassium Hydrogen Phosphate Acetonitrile (50∶50) as the mobile phase, 1.0mL/min as the flow rate at detection wavelength of 296nm. Results: For cinobufagin, the linear range was 0.67?g~4.7?g and the average recovery rate was 97.78% with RSD=1.2%. For resibufogenin, the linear range was 0.33?g~2.3?g and the average recovery was rate 99.61% with RSD=2.0%.Conclusion: The method can be applied to content determination of cinobafagin and Resibufogenin in Qianglijiuxin Dripping pills.
Palabras clave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Traditional Patent Medicine Año: 1992 Tipo del documento: Article