Value of color Doppler ultrasonography combined with coagulation test in the diagnosis of postpartum thrombosis and the prediction of thrombosis in pregnant women / 中国综合临床
Clinical Medicine of China ; (12): 272-276, 2018.
Artículo en Chino | WPRIM | ID: wpr-706667
ABSTRACT
Objective To evaluate the value of color Doppler ultrasonography combined with coagulation test in the diagnosis of postpartum thrombosis and the prediction of thrombosis in pregnant women.Methods Color Doppler ultrasonography and blood coagulation examination were performed at 1 weeks before and 1 weeks after delivery respectively.Two or more abnormalities in both examinations were defined as positive thrombus combined diagnosis,two ultrasound tests that showed " snowstorm" sign were cdefined aspositive ultrasonic diagnosis.Thrombus formation in 30d after delivery was followed up.Three-dimensional x2 test was used to compare the sensitivity and specificity of the combined diagnosis group and the ultrasonic diagnosis group.Results 238 cases were included in the study,including 76 positive cases and 162 negative cases in combined diagnosis group,103 positive cases and 135 negative cases in ultrasonic diagnosis group.At the end of the follow-up period,there were 28 cases (36.84%) of the deep venous thrombosis of the lower extremities occurred in the combined diagnosis positive group and 21 cases (20.39%) in ultrasound diagnosis positive group.Kaplan-Meier method was used to analyze the lower extremity deep vein thrombosis of the positive subjects in the two diagnostic methods.Log Rank showed that the difference between the two groups was statistically significant (x2 =5.952,P =0.015).The sensitivity and specificity of the combined diagnosis positive group were higher than those of ultrasound diagnosis positive group,the difference was statistically significant (90.32% vs.67.74%;76.81% vs.60.39%) (x2=4.00,x2=22.69,P<0.05).Conclusion Color Doppler ultrasonography combined with blood coagulation function can be used to diagnose prethrombotic state in pregnant women,and have high sensitivity and specificity for predicting deep vein thrombosis of lower extremities in pregnant women.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio diagnóstico / Estudio pronóstico Idioma: Chino Revista: Clinical Medicine of China Año: 2018 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio diagnóstico / Estudio pronóstico Idioma: Chino Revista: Clinical Medicine of China Año: 2018 Tipo del documento: Artículo