MR Findings of Breast Implant Rupture Presenting with Unusual Breast Enlargement
Investigative Magnetic Resonance Imaging
;
: 110-112, 2018.
Artículo
en Inglés
| WPRIM
| ID: wpr-740132
ABSTRACT
We report the case of a patient who presented with rupture of a silicone breast implant showing acute and chronic inflammation. Magnetic resonance imaging (MRI) showed silicone foci outside the implant shell and inside the pectoralis muscles that represented intra- and extracapsular ruptures of the implant and silicone granuloma. There were distinct fluid-fluid levels of various signal intensities and no signs of implant collapse such as ‘linguine sign.’ Rather, we detected enlargement of both the implant shell and the breast.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Músculos Pectorales
/
Rotura
/
Silicio
/
Elastómeros de Silicona
/
Siliconas
/
Mama
/
Imagen por Resonancia Magnética
/
Implantes de Mama
/
Granuloma
/
Inflamación