Your browser doesn't support javascript.
loading
In-vitro performance and fracture strength of thin monolithic zirconia crowns
The Journal of Advanced Prosthodontics ; : 79-84, 2018.
Artículo en Inglés | WPRIM | ID: wpr-742028
ABSTRACT

PURPOSE:

All-ceramic restorations required extensive tooth preparation. The purpose of this in vitro study was to investigate a minimally invasive preparation and thickness of monolithic zirconia crowns, which would provide sufficient mechanical endurance and strength. MATERIALS AND

METHODS:

Crowns with thickness of 0.2 mm (group 0.2, n=32) or of 0.5 mm (group 0.5, n=32) were milled from zirconia and fixed with resin-based adhesives (groups 0.2A, 0.5A) or zinc phosphate cements (groups 0.2C, 0.5C). Half of the samples in each subgroup (n=8) underwent thermal cycling and mechanical loading (TCML)(TC 5℃ and 55℃, 2×3,000 cycles, 2 min/cycle; ML 50 N, 1.2×106 cycles), while the other samples were stored in water (37℃/24 h). Survival rates were compared (Kaplan-Maier). The specimens surviving TCML were loaded to fracture and the maximal fracture force was determined (ANOVA; Bonferroni; α=.05). The fracture mode was analyzed.

RESULTS:

In both 0.5 groups, all crowns survived TCML, and the comparison of fracture strength among crowns with and without TCML showed no significant difference (P=.628). Four crowns in group 0.2A and all of the crowns in group 0.2C failed during TCML. The fracture strength after 24 hours of the cemented 0.2 mm-thick crowns was significantly lower than that of adhesive bonded crowns. All cemented crowns provided fracture in the crown, while about 80% of the adhesively bonded crowns fractured through crown and die.

CONCLUSION:

0.5 mm thick monolithic crowns possessed sufficient strength to endure physiologic performance, regardless of the type of cementation. Fracture strength of the 0.2 mm cemented crowns was too low for clinical application.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Zinc / Técnicas In Vitro / Agua / Cerámica / Adhesivos / Tasa de Supervivencia / Cementación / Preparación del Diente / Coronas Idioma: Inglés Revista: The Journal of Advanced Prosthodontics Año: 2018 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Zinc / Técnicas In Vitro / Agua / Cerámica / Adhesivos / Tasa de Supervivencia / Cementación / Preparación del Diente / Coronas Idioma: Inglés Revista: The Journal of Advanced Prosthodontics Año: 2018 Tipo del documento: Artículo