Fetomaternal hemorrhage in RhD-negative pregnant women in Tianjin / 国际生物医学工程杂志
International Journal of Biomedical Engineering
; (6): 139-142, 2019.
Article
en Zh
| WPRIM
| ID: wpr-751602
Biblioteca responsable:
WPRO
ABSTRACT
Objective To study and monitor the situation of femomaternal hemorrhage (FMH) in RhD-negative pregnant women in Tianjin, obtain the FMH data of such population, and analyze the relationship between FMH and age, blood type, gestational age, hemolytic disease of postpartum neonates, etc. Methods The FMH level was detected by flow cytometry with FITC-anti-HbF monoclonal antibody. The blood type was detected by blood serum method. The irregular antibody was identified by saline method and indirect anti-human ball method. The hemolysis of postpartum neonates was detected by three tests of hemolysis. Results The FMH volume of 86 RhD negative pregnant women was between 0 and 11.48 ml, with an average of 1.82 ml. There were 63.95%of pregnant women showed a volume of FMH<2.0 ml, 23.26%between 2 and 4 ml, 11.63%between 4.0 and 10.0 ml, and 1.16%>10 ml. The proportion of lower FMH in pregnant women≤30 years old was>11.71%higher than that in the pregnant women>30 years old, but the difference was no statistical significant. There was no significant difference in FMH of pregnant women with O, A, B and AB types. The proportion of higher FMH in pregnant women with compatible ABO blood type with her husband was 12.46% lower than that of the heterozygous cases, but the difference was no statistical significant. The proportion of higher FMH in the pregnant women with 28 to 32 weeks gestational age was 14.55% higher than that of ≤28 weeks and was 35.32% higher than that of >32 weeks, and the differences were statistical significant. Three samples in the 86 samples were positive for anti-D antibody, and their three hemolytic test results were strongly positive with the anti-D titer from 1:2 to 1:32 and the FMH volume from 1.50 to 6.93 ml. The proportion of lower FMH in the 10 pregnant women without postpartum hemolysis was 70% higher than that in 5 pregnant women with postpartum hemolysis, but the differences were not statistical significant. Conclusions The results suggest that monitoring FMH content by flow cytometry can reflect FMH in Rh-negative pregnant women. The studies on the relationship between FMH and age, blood type, pregnant time and hemolytic disease of postpartum neonates can provide basically experimental data for standard use of anti-D immunoglobulin in pregnant women.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
International Journal of Biomedical Engineering
Año:
2019
Tipo del documento:
Article