Brain Oxygen Monitoring via Jugular Venous Oxygen Saturation in a Patient with Fulminant Hepatic Failure / 대한구급학회지
The Korean Journal of Critical Care Medicine
;
: 251-255, 2016.
Artículo
en Inglés
| WPRIM
| ID: wpr-770945
ABSTRACT
Fulminant hepatic failure (FHF) is often accompanied by a myriad of neurologic complications, which are associated with high morbidity and mortality. Although appropriate neuromonitoring is recommended for early diagnosis and to minimize secondary brain injury, individuals with FHF usually have a high chance of coagulopathy, which limits the ability to use invasive neuromonitoring. Jugular bulb venous oxygen saturation (JvO₂) monitoring is well known as a surrogate direct measures of global brain oxygen use. We report the case of a patient with increased intracranial pressure due to FHF, in which JvO₂ was used for appropriate brain oxygen monitoring.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Oxígeno
/
Consumo de Oxígeno
/
Encéfalo
/
Edema Encefálico
/
Lesiones Encefálicas
/
Presión Intracraneal
/
Encefalopatía Hepática
/
Mortalidad
/
Fallo Hepático Agudo
/
Diagnóstico Precoz
Tipo de estudio:
Estudio diagnóstico
/
Estudio pronóstico
/
Estudio de tamizaje
Límite:
Humanos
Idioma:
Inglés
Revista:
The Korean Journal of Critical Care Medicine
Año:
2016
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS