A fluorometric method for direct detection of inorganic polyphosphate in enterohemorrhagic O157:H7 / 南方医科大学学报
Journal of Southern Medical University ; (12): 344-350, 2019.
Artículo en Chino | WPRIM | ID: wpr-772061
ABSTRACT
OBJECTIVE@#To establish a quantitative fluorescent detection method using DAPI for detecting inorganic polyphosphate (polyP) in enterohemorrhagic Escherichia coli (EHEC) O157H7.@*METHODS@#The DNA of wild-type strain of EHEC O157H7 was extracted and purified. DAPI was combined with the extracted DNA and polyP45 standards for measurement of the emission spectra at 360 nm and 415 nm fluorescence spectrophotometry. The fluorescence of DAPI-DNA and DAPI-polyP complexes was detected by fluorescence confocal microscopy to verify the feasibility of DAPI for detecting polyP. To determine the optimal pretreatment protocol for improving the cell membrane permeability, the effects of 6 pretreatments of the cells (namely snap-freezing in liquid nitrogen, freezing at -80 ℃, and freezing at -20 ℃, all followed by thawing at room temperature; heating at 60 ℃ for 10 min; treatment with Triton x-100; and placement at room temperature) were tested on the survival of EHEC O157H7. The fluorescence values of the treated bacteria were then measured after DAPI staining. A standard calibration curve of polyP standard was established for calculation of the content of polyP in the live cells of wildtype EHEC strain and two mutant strains.@*RESULTS@#At the excitation wavelength of 360 nm, the maximum emission wavelength of DAPI-DNA was 460 nm, and the maximum emission wavelength of DAPI-polyP was 550 nm at the excitation wavelength of 415 nm. The results of confocal microscopy showed that 405 nm excitation elicited blue fluorescence from DAPIDNA complex with the emission wavelength of 425-475 nm; excitation at 488 nm elicited green fluorescence from the DAPIpolyP complex with the emission wavelength of 500-560 nm of. Snap-freezing of cells at -80 ℃ followed by thawing at room temperature was the optimal pretreatment to promote DAPI penetration into the live cells. The standard calibration curve was =1849+127.5 (R=0.991) was used for determining polyP content in the EHEC strains. The experimental results showed that wild-type strain had significantly higher polyP content than the mutant strains with deletion.@*CONCLUSIONS@#We established a convenient quantitative method for direct and reliable detection polyP content to facilitate further study of polyP and its catalytic enzymes in EHEC O157H7.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Polifosfatos / Escherichia coli O157 / Proteínas de Escherichia coli Tipo de estudio: Estudio diagnóstico / Guía de Práctica Clínica Idioma: Chino Revista: Journal of Southern Medical University Año: 2019 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Polifosfatos / Escherichia coli O157 / Proteínas de Escherichia coli Tipo de estudio: Estudio diagnóstico / Guía de Práctica Clínica Idioma: Chino Revista: Journal of Southern Medical University Año: 2019 Tipo del documento: Artículo