On the effects of the characteristics of the titanium oxide to the osteoblast cell culture / 대한치과보철학회지
The Journal of Korean Academy of Prosthodontics
;
: 358-359, 2000.
Artículo
en Inglés
| WPRIM
| ID: wpr-77405
ABSTRACT
STATEMENT of PROBLEM:
Confusion about the relationship of surface characteristics of implant to osteoblast cell attachment.PURPOSE:
This study attempted to bone cell attachment to the implant surface which was modified by heat. MATERIAL ANDMETHODS:
Commercially pure titanium grade 2, 4x4mm sheet 40 pieces were treated for 10 minutes with ultrasonic cleaner with methylethyl ketone, ethanol, deionized distilled water, and half of the specimen 20 pieces were heat treated in 980degreesC for 15 minutes. All 40 specimens were autoclaves. Total 6 dishes were prepared, 3 dishes were for control group, and the other 3 dishes were for heat treatment. In fourth day, cell account was done. CONCULSION The change of surface characterization by heat treatment could affect the cell attachment in the early stage however, the change of surface characterization would not be prolonged.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Osteoblastos
/
Titanio
/
Ultrasonido
/
Agua
/
Técnicas de Cultivo de Célula
/
Etanol
/
Calor
Idioma:
Inglés
Revista:
The Journal of Korean Academy of Prosthodontics
Año:
2000
Tipo del documento:
Artículo