Review on photoacoustic tomographic image reconstruction for acoustically heterogeneous tissues / 生物医学工程学杂志
Journal of Biomedical Engineering
;
(6): 486-492, 2019.
Artículo
en Chino
| WPRIM
| ID: wpr-774181
ABSTRACT
Acoustic properties of biological tissues usually vary inhomogeneously in space. Tissues with different chemical composition often have different acoustic properties. The assumption of acoustic homogeneity may lead to blurred details, misalignment of targets and artifacts in the reconstructed photoacoustic tomography (PAT) images. This paper summarizes the main solutions to PAT imaging of acoustically heterogeneous tissues, including the variable sound speed and acoustic attenuation. The advantages and limits of the methods are discussed and the possible future development is prospected.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Acústica
/
Procesamiento de Imagen Asistido por Computador
/
Tomografía
/
Artefactos
/
Fantasmas de Imagen
Límite:
Humanos
Idioma:
Chino
Revista:
Journal of Biomedical Engineering
Año:
2019
Tipo del documento:
Artículo