Obstruction of an Endotracheal Tube with Change of the Head Position in a Trachea Deviated Patient : A case report / 대한마취과학회지
Korean Journal of Anesthesiology ; : 339-341, 2007.
Artículo en Coreano | WPRIM | ID: wpr-78415
ABSTRACT
Various causes of endotracheal tube obstruction during general anesthesia exist. Herein, the case of a 77-year old male patient, with tracheal deviation, who was intubated with an endotracheal tube in the emergency room, without a Murphy eye, is reported. He was transferred to the operating room for the removal of a subdural hematoma. The endotracheal tube suddenly became obstructed during flexion of neck for the craniotomy procedure. The distal bevel of the endotracheal tube, without Murphy eye, was discovered to have come into contact with the tracheal wall, with the airway being obstructed during the fiberoptic bronchoscopy. Shortly after extubation of the obstructed tube, an armored tube, with a Murphy eye, was reintubated, after which the respiration pattern immediately returned to normal.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Quirófanos / Respiración / Tráquea / Broncoscopía / Craneotomía / Servicio de Urgencia en Hospital / Cabeza / Hematoma Subdural / Anestesia General / Cuello Límite: Anciano / Humanos / Masculino Idioma: Coreano Revista: Korean Journal of Anesthesiology Año: 2007 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Quirófanos / Respiración / Tráquea / Broncoscopía / Craneotomía / Servicio de Urgencia en Hospital / Cabeza / Hematoma Subdural / Anestesia General / Cuello Límite: Anciano / Humanos / Masculino Idioma: Coreano Revista: Korean Journal of Anesthesiology Año: 2007 Tipo del documento: Artículo