ABSTRACT
Objective To establish the assay method for the total polysaccharide in Pudi Enema.Methods Phenol-sulfuric acid method was used for chromogenic reaction.The content of total polysaccharide was measured by UV spectrophotometry at 488.8 nm.Results The total polysaccharides calibration curve was at the range of 0~22.635 mg/L, with regression function being Y=0.062 06 X-0.003 34(r=0.999 8).The recovery of calycosin was 98.36%(RSD=2.34%).Conclusion This method is sensitive,rapid,accurate and reliable.It can be used to assay the content of total polysaccharide in Pudi Enema.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Journal of Pharmaceutical Practice Año: 2017 Tipo del documento: Artículo