Fibrin Clot Mistook as a Worm in the Intravenous Line
Yonsei Medical Journal ; : 267-269, 2020.
Artículo en Inglés | WPRIM | ID: wpr-811467
ABSTRACT
There have been several reports of foreign bodies being discovered in the intravenous set. In this case, the patient complained that he found a worm in his intravenous line. It was later confirmed as a long, white fibrin deposit by pathologic examination. This happened even though there was a non-return valve in the intravenous line. Also, since there were few red blood cells in the deposit, it did not look like a blood clot. In cases like this, we suggest that physicians keep this possibility in mind to reassure their patients.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Fibrina / Analgesia Controlada por el Paciente / Eritrocitos / Cuerpos Extraños Límite: Humanos Idioma: Inglés Revista: Yonsei Medical Journal Año: 2020 Tipo del documento: Artículo