ABSTRACT

PURPOSE:

To evaluate the diagnostic ability of optic disc topographic parameters and the retinal nerve fiber layer (RNFL) thickness parameter measured by optical coherence tomography (OCT) and to determine the association of these structural parameters with visual field indices.

METHODS:

Fifty-six glaucomatous eyes and 65 healthy control eyes were enrolled in this retrospective cross-sectional study. Each subject had a 24-2 full threshold test on a Humphrey visual field analyzer and an optical coherence tomographic evaluation. The parameters from the fast RNFL thickness algorithm and the fast optic disc algorithm were analyzed by an ROC curve, and we sought to determine the association of these parameters with visual field indices by linear and logarithmic regression.

RESULTS:

The area under the receiver operating characteristic curve (AUROC) value of the fast optic disc algorithm parameters ranged from 0.78 to 0.79 and that of the fast RNFL thickness algorithm parameters ranged from 0.74 to 0.81. The associations between the parameters from the fast optic disc algorithm and from the fast RNFL thickness algorithm with visual field indices were statistically significant (P<0.001).

CONCLUSIONS:

The fast optic disc algorithm and the fast RNFL algorithm revealed comparable diagnostic ability in discriminating glaucoma and significant associations with visual field indices.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Retinaldehído / Campos Visuales / Glaucoma / Estudios Transversales / Estudios Retrospectivos / Curva ROC / Tomografía de Coherencia Óptica / Ojo / Fibras Nerviosas Tipo de estudio: Estudio observacional / Estudio de prevalencia / Estudio pronóstico / Factores de riesgo Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Año: 2008 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Retinaldehído / Campos Visuales / Glaucoma / Estudios Transversales / Estudios Retrospectivos / Curva ROC / Tomografía de Coherencia Óptica / Ojo / Fibras Nerviosas Tipo de estudio: Estudio observacional / Estudio de prevalencia / Estudio pronóstico / Factores de riesgo Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Año: 2008 Tipo del documento: Artículo