ABSTRACT
Objective:
To establish a method by combining microwave-assisted extraction (MAE), solid phase extraction (SPE) and high performance liquid chromatography (HPLC) for determination of the mefenacet residues in rice.Methods:
Acetone and acetontrile (37) were used as extraction solvent. Microwave-assisted extraction was used to extract mefenacet residues in the rice. The extracts were then cleaned up with a Florisil cartridge and then subjected to Hypersil C18 column(5 μm,4. 6 mm × 200 mm), with acetonitrile water(50 50,V/V)solution as mobile phase and with a flow rate of 1.0 ml/min the ultraviolet detection wavelength was at 217 nm.Results:
Good linear correlation for mefenacet was found within a concentration range of 0. 198-9. 900 μg/ml. The detection limit was 0. 039 6 μg/mL for mefenacet(S/N=2). The average recovery rate of rice hull and brown rice were 90.8% (RSD 1. 8%) and 85. 6% (RSD 2. 5%),respectively.Conclusion:
The present method is simple and rapid it can be used for the determination of mefenacet residues in rice.