Successful tracheal intubation using fiberoptic bronchoscope via an I-gel(TM) supraglottic airway in a pediatric patient with Goldenhar syndrome: A case report / 대한마취과학회지
Korean Journal of Anesthesiology
;
: 61-65, 2013.
Artículo
en Inglés
| WPRIM
| ID: wpr-85959
ABSTRACT
The I-gel(TM) is a single-use supraglottic airway device introduced in 2007 which features a non-inflatable cuff and allows passage of a tracheal tube owing to its large diameter and short length of the airway tube. In this case, the authors experienced a difficult airway management on a 4-year-old boy with underlying Goldenhar syndrome who underwent a tonsillectomy. Intubation using a laryngoscope was unsuccessful at the first attempt. In the following attempt, we used the I-gel(TM) supraglottic airway for ventilation and were able to achieve successful intubation with a cuffed tube by using fiberoptic bronchoscope through the I-gel(TM) supraglottic airway. The authors suggest that I-gel(TM) is a useful device for ventilation and it has many advantages for tracheal intubation in pediatric patients with difficult airway.