Your browser doesn't support javascript.
loading
MSCT preoperative evaluation on peritoneal cancer index of patients with pseudomyxoma peritonei / 中国医学影像技术
Chinese Journal of Medical Imaging Technology ; (12): 381-385, 2019.
Artículo en Chino | WPRIM | ID: wpr-861430
ABSTRACT

Objective:

To investigate the value of MSCT in preoperative assessing operitoneal cancer index (PCI) in patients with pseudomyxoma peritonei (PMP). Methods MSCT data of histopathologically proved PMP in 108 patients were retrospectively analyzed. MSCT-PCI scores were evaluated and compared with intraoperative PCI scores, 0-8 was assigned to the omentum area, the liver area, the small omental sac area, the spleen area, the descending colon area, the left iliac area, the pelvic area, the right iliac area and the ascending colon area, respectively, whereas 9 to 12 were assigned to the small intestine area. The consistency between MSCT-PCI scores and the intraoperative PCI scores in different regions and MSCT-PCI scores in different regions between different observers were analyzed. The efficacy of MSCT in diagnosing PMP in different regions was calculated. Results Among 108 patients, the consistency between MSCT-PCI and intraoperative PCI scores in 1-3 regions was good, of 0, 4-9 regions was moderate, while of the 10-12 regions was fair. The consistency of MSCT-PCI scores in 0, 4 and 7 regions between 2 observers was better, of 1-3, 5, 8-10 regions was good, of 6, 11, 12 regions was moderate. The sensitivity of MSCT in diagnosis of PMP in 0-12 regions was 92.63% (88/95), 97.94% (95/97), 95.83% (92/96), 95.79% (91/95), 89.69% (87/97), 95.00% (95/100), 96.08% (98/102), 96.12% (99/103), 94.90% (93/98), 87.78% (79/90), 88.89% (80/90), 86.17% (81/94) and 85.71% (84/98); the specificity was 84.62% (11/13), 100% (11/11), 91.67% (11/12), 84.62% (11/13), 100% (11/11), 87.50% (7/8), 83.33% (5/6), 100% (5/5), 100% (10/10), 83.33% (15/18), 83.33% (15/18), 85.71% (12/14) and 80.00% (8/10); and the accuracy was 91.67% (99/108), 98.15% (106/108), 95.37% (103/108), 94.44% (102/108), 90.74% (98/108), 94.44% (102/108), 95.37% (103/108), 96.30% (104/108), 95.37% (103/108), 87.04% (94/108), 87.96% (95/108), 86.11% (93/108) and 85.19% (92/108). Conclusion MSCT can accurately assess PCI of PMP, therefore providing references for clinical development of treatment plan.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Medical Imaging Technology Año: 2019 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Medical Imaging Technology Año: 2019 Tipo del documento: Artículo