Feasibility of 3.0T closed MR-guided microwave ablation for liver metastases / 中国介入影像与治疗学
Chinese Journal of Interventional Imaging and Therapy
;
(12): 454-458, 2020.
Artículo
en Chino
| WPRIM
| ID: wpr-861935
ABSTRACT
Objective:
To explore the feasibility of 3.0T closed MR-guided microwave ablation for liver metastases.Methods:
Totally 14 patients with 23 liver metastases were treated with 3.0T closed MR-guided microwave ablation. The technical success rate, ablation parameters, procedures time and complications were recorded, and the local ablation effects were evaluated 1 month later.Results:
The technical success rate was 100%. The ablation power was (65.65±4.11)W, the ablation time of single lesion was (13.92±6.36)min, and the total operation time was (68.48±19.50)min. No severe complication such as liver abscess, diaphragmatic perforation nor jaundice occurred, while small amount of pleural effusion was obserevd in 2 cases (2/14, 14.29%). One month later, the complete ablation rate was 91.30% (21/23).Conclusion:
3.0T closed MR-guided microwave ablation is safe and effective for treating liver metastases.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Idioma:
Chino
Revista:
Chinese Journal of Interventional Imaging and Therapy
Año:
2020
Tipo del documento: