One Case of Displacement of Copper - T IUD into Urinary Bladder / 대한산부인과학회잡지
Korean Journal of Obstetrics and Gynecology ; : 396-399, 1999.
Artículo en Coreano | WPRIM | ID: wpr-86770
ABSTRACT
Uterine perforation is a serious complication in users of intrauterine devices for contraception. Authors encountered one case of displacement of Copper-T IVD into urinary blpossibly due to uterine perforation on insertion of the Copper-T IUD in a 28 year old 1-multipara, who experienced normal intrauterine pregnancy in the circumstances. This patient was in silent, asymptomatic condition and underwent cesarean section. And Copper-T IUD was removed under the cystotomy. So we report one case with brief review of literatures
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Perforación Uterina / Vejiga Urinaria / Cesárea / Anticoncepción / Cobre / Cistotomía / Enfermedades Asintomáticas / Dispositivos Intrauterinos Límite: Adulto / Femenino / Humanos / Embarazo Idioma: Coreano Revista: Korean Journal of Obstetrics and Gynecology Año: 1999 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Perforación Uterina / Vejiga Urinaria / Cesárea / Anticoncepción / Cobre / Cistotomía / Enfermedades Asintomáticas / Dispositivos Intrauterinos Límite: Adulto / Femenino / Humanos / Embarazo Idioma: Coreano Revista: Korean Journal of Obstetrics and Gynecology Año: 1999 Tipo del documento: Artículo