ABSTRACT
Objective:To compare the differences of fluoroscopy time and dose between HIS bundle pacing and right ventricle apex pacing.Methods:This study includes thirty patients undergoing HIS bundle pacing (HIS group) and 32 patients undergoing right ventricular apex pacing (RVA group). The fluoroscopy time and cumulative dose (CD) to patients during surgery were recorded and analyzed.Results:The operation time for patients in HIS group and RVA group were (76.8±13.1) and (66.0±10.8) min ( t=3.386, P<0.001), respectively. The fluoroscopy time was (698.2±113.7) and (293.3±63.9) s ( t=14.709, P<0.001) and the CD were (391.3±70.0) and (162.3±40.5) mGy ( t=13.694, P<0.001) in HBP group and RVA group, respectively. In comparison, the fluoroscopy time and CD for HIS bundle electrode implantation were (501.2±112.3) s and (279.9±65.0) mGy, respectively, significantly higher than in the case of RVA, where the values were (103.4±30.6) s and (57.3±13.8) mGy ( t=15.864, Z=-6.524, P<0.001). Conclusions:Compared with right ventricular apical pacing, the HIS bundle pacing takes longer operation time, leading to higher radiation dose, which should be prudently selected.