Your browser doesn't support javascript.
loading
Accuracy of glomerular filtration rate measured by 99Tc m-DTPA renal dynamic imaging (Gates method) in heart transplant recipients / 中华核医学与分子影像杂志
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 406-410, 2020.
Artículo en Chino | WPRIM | ID: wpr-869180
ABSTRACT

Objective:

To evaluate the accuracy of glomerular filtration rate (GFR) assessed from the renal dynamic imaging method (Gates method) with 99Tc m-diethylene triamine pentoacetic acid (DTPA) in the heart transplant population.

Methods:

From September 2017 to June 2018, 34 patients with advanced heart failure who were prepared for surgery (30 males, 4 females; age (45±14) years; heart transplant group) and 41 patients with normal heart function (19 males, 22 females; age (50±17) years; control group) in Fuwai Hospital were respectively enrolled. GFRs of all patients were measured using Gates method (gGFR) and dual plasma sample method (DPSM; dGFR) with 99Tc m-DTPA. The accuracy of Gates method for detecting GRF was verified by using DPSM as the reference. Seventeen patients in heart transplant group underwent 99Tc m-DTPA renal dynamic imaging for Gates and DPSM results repeatedly after the surgery. The single kidney (left and right) functions (dGFRL and dGFRR) of DPSM were obtained according to the results of Gates method. Pearson correlation analysis and paired t test were used to analyze the data.

Results:

The gGFR in heart transplant group was higher than dGFR ((66.49±15.66) vs (49.16±13.24) ml·min -1·1.73 m -2; t=6.728, P<0.01), and there was a moderate correlation between them ( r=0.467, P<0.01). No difference between gGFR and dGFR in control group was observed ((65.35±26.28) vs (62.22±21.37) ml·min -1·1.73 m -2; t=1.268, P=0.212), and there was a good correlation between them ( r=0.799, P<0.01). The difference between 2 correlation coefficients was statistically significant ( z=-2.44, P<0.05). Serum creatinine decreased, while dGFR, dGFRL and dGFRR increased after the surgery, suggesting the improved renal function.

Conclusions:

The renal dynamic imaging method (Gates method) with 99Tc m-DTPA has less accuracy in the heart transplant patients. Combination of DPSM and Gates method can provide the precise total GFR and assess single kidney GFR, and may serve as a tool to monitor the renal function for the heart transplant patients in clinic.
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Nuclear Medicine and Molecular Imaging Año: 2020 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Nuclear Medicine and Molecular Imaging Año: 2020 Tipo del documento: Artículo