ABSTRACT
@#

Introduction:

Haemolytic specimens are a frequent occurrence in clinical laboratories, and they interfere with the analysis of many tests. Case report We describe here an unusual case of leptospirosis complicated by haemolytic anaemia in a 70-year-old man with established kidney failure. He presented with an abrupt onset of shortness of breath, flushing and erythematous rash after completing haemodialysis. The patient’s biochemistry test samples were however rejected twice as they were grossly haemolysed. The integrated auto-verification alert system implemented in the hospital’s laboratory information system alerted the staff of the possibility of in vivo haemolysis.

Discussion:

The auto-verification alert system effectively distinguishes between in vitro and in vivo haemolysis and as such can be utilised as a diagnostic aid in patients with suspected intravascular haemolysis. Keywords

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Inglés Revista: The Malaysian Journal of Pathology Año: 2021 Tipo del documento: Artículo