ABSTRACT
BACKGROUND@#Normal tension glaucoma (NTG) is a less pressure-dependent type of glaucoma with characteristic optic neuropathy. Recently, the biomechanical mechanism has been thought to account for glaucomatous optic neuropathy to some degree. We intended to compare dynamic corneal response parameters (DCRs) among patients with primary open-angle glaucoma with normal tension or hypertension and controls. The correlations between DCRs and known risk factors for glaucoma were also analyzed.@*METHODS@#In this cross-sectional study, 49 NTG subjects, 45 hypertension glaucoma (HTG) subjects, and 50 control subjects were enrolled. We compared the differences in DCRs using corneal visualization Scheimpflug technology among the NTG, HTG, and control groups. We also analyzed the correlations between DCRs and known risk factors for glaucoma (eg, central corneal thickness [CCT], intraocular pressure [IOP], etc).@*RESULTS@#The maximum inverse concave radius (NTG 0.18 [0.17, 0.20] mm-1; control 0.17 [0.16, 0.18] mm-1; P = 0.033), deformation amplitude ratio of 2 mm (DAR 2 mm, NTG 4.87 [4.33, 5.39]; control 4.37 [4.07, 4.88]; P  0.05). In the univariate and multivariate analyses, some of the DCRs, such as IR, were negatively correlated with CCT and IOP, whereas SP-A1 was positively correlated with CCT and IOP.@*CONCLUSIONS@#The cornea was more deformable in NTG than in HTG or controls. There were no significant differences in corneal deformability between HTG and controls. The cornea was more deformable with the thinner cornea and lower IOP.
Asunto(s)
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Fenómenos Biomecánicos / Glaucoma de Ángulo Abierto / Estudios Transversales / Córnea / Glaucoma de Baja Tensión / Hipertensión / Presión Intraocular Tipo de estudio: Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Humanos Idioma: Inglés Revista: Chinese Medical Journal Año: 2021 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Fenómenos Biomecánicos / Glaucoma de Ángulo Abierto / Estudios Transversales / Córnea / Glaucoma de Baja Tensión / Hipertensión / Presión Intraocular Tipo de estudio: Estudio observacional / Estudio de prevalencia / Factores de riesgo Límite: Humanos Idioma: Inglés Revista: Chinese Medical Journal Año: 2021 Tipo del documento: Artículo