Establishment and validation of the dose-response curve of X-rays irradiation and chromosome aberrations in human peripheral blood cells / 中国职业医学
China Occupational Medicine ; (6): 705-708, 2019.
Artículo en Chino | WPRIM | ID: wpr-881847
ABSTRACT

OBJECTIVE:

To explore the dose-effect of X-ray irradiation and chromosome aberrations in human peripheral blood cells,and establish a dose-response curve of dicentric and ring(dic+r)aberration induced by X-ray irradiation.

METHODS:

Human peripheral blood samples were collected from three healthy individuals and were exposed to X-ray at the doses of 0.00,0.25,0.50,0.75,1.00,2.00,3.00,4.00 and 5.00 Gy in vitro.The dose rate was 1.158 Gy/min.The blood cells were harvested after routine culture,and the chromosome preparation was carried out.The dicentrics and rings in metaphase cells were counted under microscope,and a dose-response curve was fitted by using the software of CABAS.Dose estimation was performed according to the curve from two blind samples.

RESULTS:

Aberration of dic+r increased with irradiation doses in the range of 0.00-5.00 Gy(P<0.01).The dose-response relationship followed a linear-quadratic equation■,where■ is the yield of dic+r,and D is the irradiated dose.The estimated doses of the two blind samples were in accordance with the actual doses.

CONCLUSION:

The dose-response curve and mathematical model of chromosome aberration following exposure to 0.00-5.00 Gy X-ray irradiation is established in this study provide a reliable method for the accurate dose estimation.