Thrombolytic Therapy for Repeated Prosthetic Valvular Thrombosis That's Associated with Pregnancy under Heparin Anticoagulation / 대한흉부외과학회지
Article en Ko | WPRIM | ID: wpr-89141
Biblioteca responsable: WPRO
ABSTRACT
During long-term anticoagulation treatment with using heparin in a pregnant patient with a mechanical mitral prosthesis, we observed several anticoagulation-related complications, including repeated prosthetic valve thrombosis. This was found to be caused by heparin resistance due to an anti-thrombin III deficiency. Thrombolytic therapy using urokinase or tissue plasminogen activator (tPA) was successful and safe for her as well as her baby.
Asunto(s)
Palabras clave
Texto completo: 1 Índice: WPRIM Asunto principal: Prótesis e Implantes / Trombosis / Falla de Prótesis / Heparina / Activador de Plasminógeno de Tipo Uroquinasa / Terapia Trombolítica / Antitrombina III / Activador de Tejido Plasminógeno / Anticoagulantes Límite: Humans / Pregnancy Idioma: Ko Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Año: 2008 Tipo del documento: Article
Texto completo: 1 Índice: WPRIM Asunto principal: Prótesis e Implantes / Trombosis / Falla de Prótesis / Heparina / Activador de Plasminógeno de Tipo Uroquinasa / Terapia Trombolítica / Antitrombina III / Activador de Tejido Plasminógeno / Anticoagulantes Límite: Humans / Pregnancy Idioma: Ko Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Año: 2008 Tipo del documento: Article