Your browser doesn't support javascript.
loading
Successful Endotracheal Intubation Using Suction-Assisted Laryngoscopy Assisted Decontamination Technique and a Head-Down Tilt Position during Massive Regurgitation
Soonchunhyang Medical Science ; : 75-79, 2020.
Artículo en Inglés | WPRIM | ID: wpr-895717
ABSTRACT
Some of the challenges in intensive care, anesthesia, and emergency medicine would be airway management in an actively vomiting patient or a bloody airway. We experienced a patient with an excessively full stomach (at least 3 L) due to gastric outlet obstruction, although he was scheduled for elective surgery. Despite such circumstances, we successfully intubated him using the suctionassisted laryngoscopy assisted decontamination technique with the patient in a head-down tilt position during massive regurgitation while avoiding resultant pulmonary aspiration.
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Inglés Revista: Soonchunhyang Medical Science Año: 2020 Tipo del documento: Artículo