Efficacy of combined application of glycine powder air-polishing in non-surgical treatment of peri-implant diseases / 北京大学学报(医学版)
Beijing Da Xue Xue Bao
; (6): 119-125, 2022.
Article
en Zh
| WPRIM
| ID: wpr-936122
Biblioteca responsable:
WPRO
ABSTRACT
OBJECTIVE@#To compare the clinical efficacy of combined application of glycine powder air-polishing and mechanical submucosal debridement in non-surgical treatment of peri-implant diseases.@*METHODS@#A randomized controlled clinical study was carried out on patients diagnosed with peri-implant diseases in the Department of Periodontology, Peking University School and Hospital of Stomatology, between May of 2020 and June of 2021.Twenty-eight patients with totally sixty-two implants were enrolled.The patients were randomly divided into the test group and control group. The patients in the test group (13 subjects/32 implants) received mechanical submucosal debridement using titanium curettes combined with application of glycine powder air-polishing, while the control group (15 subjects/30 implants) received mechanical submucosal debridement using titanium only. Clinical parameters, such as plaque index (PLI), pocket probing depth (PPD), bleeding index (BI) and the percentage of suppuration on probing on implants' level (SoP%) were measured at baseline and 8 weeks after non-surgical intervention. Changes and group differences of clinical parameters of the implants before and 8 weeks after non-surgical intervention were compared.@*RESULTS@#Mean PLI, PPD, BI of both the test group and control group significantly reduced 8 weeks after non-surgical intervention (P < 0.05). Compared with the control group, the test group achieved lower BI (2.7±0.8 vs. 2.2±0.7, P < 0.05), more reduction of BI (0.6±0.7 vs. 1.1±0.6, P < 0.01) and more reduction of SoP% (21.9% vs. 10%, P < 0.05) after non-surgical intervention. Both the control and test groups exhibited comparable PLI and PPD reductions (P>0.05). For the implants diagnosed with peri-implant mucositis, the test group revealed more signi-ficant reduction in BI and SoP% than the control group (1.0±0.7 vs. 0.4±0.7, P=0.02; 6.3% vs. 0, P=0.012). There was no significant difference existing in PLI and PD improvement between the control group and test group (P>0.05). For the implants diagnosed with peri-implantitis, there was no significant difference existing in PLI, PPD, BI and SoP% improvement values between the test and control groups (P>0.05). No complications or discomforts were reported during the study.@*CONCLUSION@#Both treatment procedures could relieve the inflammation of peri-implant soft tissue. Non-surgical mechanical submucosal debridement combined application of glycine powder air-polishing is associated with significant reduction of soft tissue bleeding and suppuration on probing especially in the implants diagnosed with peri-implant mucositis.
Palabras clave
Texto completo:
1
Índice:
WPRIM
Asunto principal:
Periodoncia
/
Polvos
/
Implantes Dentales
/
Índice Periodontal
/
Resultado del Tratamiento
/
Periimplantitis
/
Glicina
Tipo de estudio:
Clinical_trials
Límite:
Humans
Idioma:
Zh
Revista:
Beijing Da Xue Xue Bao
Año:
2022
Tipo del documento:
Article