Laparoscopic Partial Nephrectomy Using a Water (Hydro)-Jet System: A Case Report
Korean Journal of Urological Oncology
;
: 138-142, 2015.
Artículo
en Inglés
| WPRIM
| ID: wpr-93647
ABSTRACT
The water-jet system (WJS) can be used for selective dissection of kidney parenchyma without renal artery clamping in laparoscopic partial nephrectomy (LPN). We report our experiences regarding LPN with a WJS. The first case was a 59 year old male with a 1.8 cm solid mass in the Rt. mid-lateral area (R.E.N.A.L score 5a). The second case was a 24 year old female with a 2.3cm solid mass in the Lt. mid-lateral area (R.E.N.A.L score 7x). We successfully finished non-clamping LPN using a WJS without perioperative complications. Surgical margins were negative (7mm and 1mm for cases 1 and 2, respectively). Post-operative renal function was not decreased significantly. LPN using a WJS is a feasible and safe technique which can be performed for small renal masses without ischemic damage.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Arteria Renal
/
Agua
/
Laparoscopía
/
Constricción
/
Riñón
/
Nefrectomía
Límite:
Femenino
/
Humanos
/
Masculino
Idioma:
Inglés
Revista:
Korean Journal of Urological Oncology
Año:
2015
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS