Your browser doesn't support javascript.
loading
Integrating magnetization transfer imaging and fat suppression T 2WI for predicting the clinical activity of Graves ophthalmopathy / 中华放射学杂志
Chinese Journal of Radiology ; (12): 996-1000, 2022.
Artículo en Chino | WPRIM | ID: wpr-956753
ABSTRACT

Objective:

To investigate the value of magnetization transfer imaging (MTI) and fat suppression T 2WI (FS-T 2WI) in predicting the clinical activity of Graves ophthalmopathy (GO).

Methods:

From October 2020 to July 2021, 64 GO patients were prospectively enrolled in the First Affiliated Hospital of Nanjing Medical University. According to the clinical activity score (CAS), the patients were divided into active group (CAS≥3, 39 patients and 78 eyes) and inactive group (CAS<3, 25 patients and 50 eyes). The coronal MTI and FS-T 2WI were scanned for pre-treatment assessment. Magnetization transfer ratio (MTR) of extraocular muscles, and signal intensity ratio (SIR) between extraocular muscles and temporalis were measured, respectively. The independent-sample t-test was used to compare the MTR and SIR between two groups. The correlations between MRI parameters and CAS were analyzed using Spearman correlation analysis. The receiver operating characteristic (ROC) curve was performed to evaluate the value of each and combined parameters for predicting the clinical activity of GO. The DeLong test was used to compare the area under the curve (AUC).

Results:

The MTR of active group and inactive group were 0.45±0.04 and 0.51±0.04, respectively, the difference was statistically significant ( t=7.62, P<0.001). The SIR were 3.4±0.6 and 2.6±0.5, respectively, and the difference was also statistically significant ( t=-8.20, P<0.001). MTR was negatively correlated with CAS ( r=-0.46, P<0.001), while SIR was positively correlated with CAS ( r=0.63, P<0.001). The AUC of MTR, SIR and the combination of MTR and SIR for predicting the clinical activity of GO were 0.840, 0.845 and 0.905, respectively. The combination of MTR and SIR showed higher performance than MTR or SIR alone, and the differences were statistically significant ( Z=2.61, P=0.009; Z=2.15, P=0.032).

Conclusions:

The quantitative parameters of MTI and FS-T 2WI, namely MTR and SIR, can be used to evaluate the clinical activity of GO. Integrating MTI and FS-T 2WI can improve the diagnostic efficiency.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Radiology Año: 2022 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Radiology Año: 2022 Tipo del documento: Artículo