Your browser doesn't support javascript.
loading
Consistency comparison of programmed cell death 1-ligand 1 in different immuno-histochemical staining methods / 北京大学学报(医学版)
Journal of Peking University(Health Sciences) ; (6): 339-342, 2023.
Artículo en Chino | WPRIM | ID: wpr-986858
ABSTRACT
OBJECTIVE@#To compare the consistency of programmed cell death 1-ligand 1 (PD-L1, clone E1L3N, 22C3, SP263) in different immunohistochemical staining methods.@*METHODS@#The first step was to select the optimal process The PD-L1(clone E1L3N) antibody recommended process, self-built process ①, self-built process ② and self-built process ③ were used to perform immunohistochemical staining in 5 cases of tonsil tissue. The quality of all slides was scored by expert pathologists (0-6 points). The process with the highest score was selected. The second step was to compare the consistency between the optimal procedure and the two standard procedures. Thirty-two cases of lung non-small cell carcinoma diagnosed by pathology in Peking University First Hospital in the past two years were randomly selected. The 32 cases were stained in parallel with the SP263 and 22C3 standard procedures, and all stained slides were scored by specialized pathologists for tumor proportion score (TPS). The scoring results were grouped according to < 1%, ≥1% to < 10%, ≥10% to < 50%, and ≥50%. The consistency of PD-L1 detection antibody clone E1L3N and 22C3, E1L3N and SP263 staining results was analyzed.@*RESULTS@#Tonsil stained slides scores (0-6 points) were as follows The recommended protocol was 5, 5, 5, 5 and 5. The self-built process ① was 5, 6, 6, 5 and 6. The self-built process ② was 4, 4, 4, 4 and 4.The self-built process ③ was 3, 3, 3, 3 and 3. The self-built process ① was the best with the highest score. The TPSs of 32 non small cell lung carcinoma (NSCLC) cases were as follows Of self-built process ①, 6 cases were lower than 1%, 5 cases were from 1% to 10%, 10 cases were from 10% to 50%, and 11 cases were higher than 50%; of 22C3 standard procedure, 5 cases were lower than 1%, 3 cases were from 1% to 10%, 13 cases were from 10% to 50%, 11 cases were higher than 50%; of SP263 standard procedure, 7 cases were lower than 1%, 4 cases were from 1% to 10%, 11 cases were from 10% to 50%, 10 cases were higher than 50%. The results of the consistency test were as follows The κ value for self-built process ① and 22C3 standard procedure was 0.736 (P < 0.001), the agreement was good; the κ value for self-built process ① and SP263 standard procedure was 0.914 (P < 0.001), the agreement was very good.@*CONCLUSION@#The immunostaining using PD-L1(E1L3N) with validated self-built staining protocol ① by Ventana Benchmark GX platform can obtain high quality of slides, and the TPSs based on these slides are in good agreement with 22C3 and SP263 standard procedures.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Coloración y Etiquetado / Inmunohistoquímica / Apoptosis / Carcinoma de Pulmón de Células no Pequeñas / Antígeno B7-H1 / Ligandos / Neoplasias Pulmonares / Anticuerpos Límite: Humanos Idioma: Chino Revista: Journal of Peking University(Health Sciences) Año: 2023 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Coloración y Etiquetado / Inmunohistoquímica / Apoptosis / Carcinoma de Pulmón de Células no Pequeñas / Antígeno B7-H1 / Ligandos / Neoplasias Pulmonares / Anticuerpos Límite: Humanos Idioma: Chino Revista: Journal of Peking University(Health Sciences) Año: 2023 Tipo del documento: Artículo