Establishment of contralateral arteriovenous fistula by using the waste vein on the side of central venous lesion: a case report / 中华肾脏病杂志
Chinese Journal of Nephrology
;
(12): 36-38, 2023.
Artículo
en Chino
| WPRIM
| ID: wpr-994948
ABSTRACT
Central venous lesion is a difficult problem in the vascular access complications of hemodialysis, which can cause serious clinical symptoms and affect the quality of hemodialysis and life of patients. We established arteriovenous fistula of the contralateral graft blood vessel with the used vein on the diseased side of the central vein of the patient. The arteriovenous fistula of the graft blood vessel was successfully punctured and hemodialysis was performed 2 weeks later. In this way, we not only solved the problem of venous hypertension and subsequent vascular access in the patient, but also reserved more vascular resources.