Your browser doesn't support javascript.
loading
Development and verification of multiplex fluorescence quantitative PCR (Taqman probe) for detection of telomerase activity / 中国生物制品学杂志
Chinese Journal of Biologicals ; (12): 1218-1223, 2023.
Artículo en Chino | WPRIM | ID: wpr-996681
ABSTRACT
@#Objective To develop and verify a multiplex fluorescence quantitative PCR(Taqman probe) method for the detection of telomerase activity.Methods Specific reverse transcription primers,two pairs of quantitative primers and probes were designed for the CDS sequence of telomerase catalytic subunit telomerase reverse transcriptase(TERT).After optimization of the reverse transcription primers(specific reverse transcription primers and random primers) and quantitative primers(two pairs of quantitative primer probes used alone or in combination) in the reaction system,with the primer probe of internal reference gene GAPDH,multiplex fluorescence quantitative PCR was performed in a single tube.In addition,telomerase positive standard and negative standard were prepared with 293T and MRC-5 cells respectively,and the stability and precision of the method were verified.The telomerase activity in 19 normal mesenchymal cell samples and 32 breast cancer cell samples were detected by the developed method.Results The optimum reaction system was as followsusing cDNA synthesized with specific reverse transcription primers as the template,2 pairs of quantitative primer probes of TERT gene were mixed with internal reference gene GAPDH primer probes for multiplex fluorescence quantitative PCR reaction in a single tube.After optimization,the sensitivity and TERT fluorescence signal quantity of the system were greatly improved,and the &Delta;Rn was enhanced by 3 times.The amplification curve of positive standard TERT gene was normal,and the &Delta;Ct between TERT gene and GAPDH gene remained stable.The amplification curve of GAPDH gene in negative standard was normal,while there was no amplification curve of TERT gene.There was a little difference in &Delta;Ct between TERT and GAPDH genes in the positive standard frozen and thawed for 3 and 5 times repeatedly and the positive standard without freezing and thawing,and the CVs of precision in intra-and inter-groups were all less than 1%.Telomerase activity was negative in 19 normal mesenchymal cell samples and positive in 32 breast cancer cell samples,and significant difference in Ct value of TERT gene between them was observed(t=4.236,P <0.001).Conclusion The developed multiplex fluorescence quantitative PCR(Taqman probe) method for the detection of telomerase activity has good stability and precision,which is expected to be used in early diagnosis and gene therapy of tumors.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Biologicals Año: 2023 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Biologicals Año: 2023 Tipo del documento: Artículo