Your browser doesn't support javascript.
loading
Mortalidad y factores relacionados al fracaso del destete de la ventilación mecánica en una unidad de cuidados intensivos de Lima, Perú / Mortality and factors related to failure to weaning from mechanical ventilation in an intensive care unit in Lima, Peru
Fernández Merjildo, Diana; Porras García, Willy; León Rabanal, Cristian; Zegarra Piérola, Jaime.
  • Fernández Merjildo, Diana; Hospital Cayetano Heredia. Lima. PE
  • Porras García, Willy; Hospital Cayetano Heredia. Lima. PE
  • León Rabanal, Cristian; Hospital Cayetano Heredia. Lima. PE
  • Zegarra Piérola, Jaime; Hospital Cayetano Heredia. Lima. PE
Rev. méd. hered ; 30(1): 5-11, ene.-mar. 2019. tab
Article Dans Es | LILACS, LIPECS | ID: biblio-1014339
Responsable en Bibliothèque : PE1.1
RESUMEN

Objetivos:

Estimar la mortalidad global, la mortalidad relacionada a los tipos de destete de pacientes en ventilación mecánica y describir los factores relacionados al fracaso del destete en una unidad de cuidados intensivos. Material y

métodos:

Estudio observacional, descriptivo. Se incluyeron 147 pacientes sometidos a destete de ventilación mecánica invasiva que ingresaron con el diagnóstico de Insuficiencia Respiratoria Aguda a la unidad de cuidados intensivos del Hospital Cayetano Heredia durante el año 2014.

Resultados:

La mortalidad global de los pacientes sometidos a destete de ventilación mecánica fue 27%, se observó mayor mortalidad en el grupo destete prolongado 42%, seguido por destete difícil 29% y destete simple 15% (p=0,039); la mortalidad global incrementó conforme aumentó la estancia en la unidad de cuidados intensivos y los días en ventilación mecánica, los factores relacionados a fracaso del destete fueron la disminución del nivel de consciencia (Escala de coma de Glasgow < 8puntos) y agitación (p=0,018).

Conclusiones:

El destete prolongado estuvo relacionado al incremento de la mortalidad en pacientes que ingresaron a ventilación mecánica invasiva por insuficiencia respiratoria aguda, los factores relacionados al fracaso del destete fueron, disminución del nivel de consciencia (Escala de coma de Glasgow <8puntos) y agitación. (AU)
ABSTRACT

Objectives:

To estimate the overall mortality and mortality related to types of weaning from mechanical ventilation as well as to describe factors related to failure in weaning in an intensive care unit (ICU).

Methods:

An observational study was carried-out among 147 patients undergoing weaning from mechanical ventilations who were admitted with the diagnosis of acute respiratory failure to the intensive care unit of Hospital Cayetano Heredia in 2014.

Results:

overall mortality in weaned patients was 27%; higher mortality (42%) was observed among those with prolonged weaning, followed by those with difficult weaning (29%) and simple weaning (15%, p=0.039). The overall mortality increased with longer stay at ICU and longer duration of mechanical ventilation. Factors related to failure in achieving weaning were low level of conscience (Glasgow coma score <8) and agitation (p=0,018).

Conclusions:

Prolonged weaning was associated to increased mortality in patients on mechanical ventilation due to acute respiratory failure. Factors related to weaning failure were related to the level of conscience. (AU)
Sujets)


Texte intégral: 1 Indice: LILACS Sujet Principal: Ventilation artificielle / Sevrage / Mortalité Type d'étude: Observational_studies / Prognostic_studies Limites du sujet: Female / Humans / Male Pays comme sujet: America do sul / Peru langue: Es Texte intégral: Rev. méd. hered Thème du journal: MEDICINA Année: 2019 Type: Article

Texte intégral: 1 Indice: LILACS Sujet Principal: Ventilation artificielle / Sevrage / Mortalité Type d'étude: Observational_studies / Prognostic_studies Limites du sujet: Female / Humans / Male Pays comme sujet: America do sul / Peru langue: Es Texte intégral: Rev. méd. hered Thème du journal: MEDICINA Année: 2019 Type: Article