Autologous whole Blood Patch in Repair of Leaking Filtering Bleds : Case Report on Initial Experience
port harcourt med. J
;
2(1): 78-80, 2007.
Article
Dans Anglais
| AIM
| ID: biblio-1274035
ABSTRACT
Aim:
To show the value of autologous whole blood patch in the management of leaking filtering blebs in Nigerian eyes.Methods:
Two male patients who had trabeculectomy and adjunctive application of mitomycin C subsequently developed leaking blebs at the University of Benin Teaching Hospital; Benin City; Nigeria. A 27-gauge needle was used to inject 0.75- 1.0ml of whole blood under the conjunctival buttonhole.Result:
The procedure succeeded in arresting the bleb leak but the trabeculectomy failed after 7 and 10 months respectively. Repeat trabeculectomy using another site remained successful after 2 years and 18 months respectively.Conclusion:
Autologous whole blood patch is successful in sealing leaking blebs complications following trabeculectomy